Extron Mlc 226 Ip User Manual

Specifications — MLC 226 Series

  1. Mlc 226 Ip
  2. Extron Mlc 226
  3. Extron Mlc 104 Ip Plus
  4. Extron Mlc 226 Ip Aap
  5. Extron Mlc 226 Ip

View and Download Extron electronics MLC 226 Series user manual online. MLC 226 Series Controller pdf manual download. Also for: Medialink mlc 226 series. Extron Electronics MLC 104 IP Plus Series Setup Guide User Manual. What to set up in gc, Control — serial (config) 4, Mlc 104 ip plus series. setup guide (continued), Players, and dvd players. Extron Electronics Hardware.

IP Intercom

Connection type (IPI–MLC).........

RJ-45 jack for CAT 5, CAT 5e, or CAT 6 cable

Audio

Frequency response...........

20 Hz to 3.3 kHz, ±1 dB

Audio processing

Audio format..............

PCM, µ-law companded

Sampling rate.............

8 kHz

Sample size.................

16 bit, µ-law companded to 8 bit

Audio latency.............

Software: 30 ms through 160 ms

Network: <150 ms, typical

Audio output

Number/signal type.........

1 mono (for use with an optional IP Intercom)

Line level output................

-10 dBV (316 mVrms), unbalanced (via 3.5 mm captive screw connector,

2 pole)

Communication

Transport bandwidth for IPI control and audio, half duplex

80 kbps (0.08% of 100Base-T

Ethernet protocol...............

TCP/IP (control), UDP (audio)

Control — host ports

Serial host port...............................

2 bidirectional RS-232: 1 rear panel 9-pin female D connector (shared with

digital input), 1 front panel 2.5 mm mini stereo jack

Baud rate and protocol..................

38400, 8 data bits, 1 stop bit, no parity

Serial control pin configurations.

9-pin female D connector: 2 = TX, 3 = RX, 5 = GND

Mini stereo jack: tip = TX, ring = RX, sleeve = GND

Ethernet host port..........................

1 RJ-45 female

Ethernet data rate (for network communication)

10/100Base-T, half/full duplex with autodetect

Ethernet protocol...........................

ARP, DHCP, ICMP (ping), TCP/IP, Telnet, HTTP, SMTP

Ethernet default settings...............

Link speed and duplex level = autodetected

IP address = 192.168.254.254

Subnet mask = 255.255.0.0

Default gateway = 0.0.0.0

DHCP = off

Web server......................................

Up to 200 simultaneous sessions

7.25 MB nonvolatile user memory

Secondary control panel (SCP)....

(1) 3.5 mm 5-pole direct insertion captive screw connector (shared with

control module and IR Link port)

IR remote control...........................

IR 402 (optional)

Front panel: 30' maximum, 40 degrees off axis

Rear panel: 38 kHz, hardwired, modulated

Program control.............................

Extron's configuration program for Windows®

Extron's Simple Instruction Set (SIS)

Microsoft® Internet Explorer, Telnet

IR learning frequencies.................

30 kHz to 62 kHz

IR learning distance.......................

2' (5.1 cm) to 12' (30.5 cm) from the front panel

Control — relay

Number/type.................................

6 momentary or latching (configurable via software)

Connectors......................................

(3) 3.5 mm captive screw connectors, 3 pole

Connector configuration...............

Groups A, B, C; each with 1 common and 2 normally open relays (default)

Contact rating.................................

24 V, 1 A

Extron MLC 226 Series MediaLink® Controllers • Specifications

1

Specifications — MLC 226 Series, cont’d

Control — serial ports

Display control port......................

(1)

3.5 mm direct insertion captive screw connector, 3 pole, programmable

for bidirectional RS-232 control (±5 V) or TTL level (0 to 5 V) infrared control

up to 1 MHz

Switcher control port.....................

(1)

3.5 mm direct insertion captive screw connector, 3 pole, for bidirectional

RS-232 control (±5 V)

Baud rate and protocol (RS-232).. 115200 to 300 baud (9600 baud = default); 8 (default) or 7 data bits; 1(default) or 2 stop bits; no parity (default), or even or odd parity

Control— IR/serial ports

IR/serial control ports...................

(3) 3.5 mm direct insertion captive screw connectors, 2 pole

Programmable: unidirectional RS-232 (±5 V) control, or TTL level (0 to 5 V)

infrared control up to 1 MHz

Baud rate and protocol..................

115200 to 300 baud (9600 baud = default) ; 8 (default) or 7 data bits;

1(default) or 2 stop bits; no parity (default), or even or odd parity

Digital I/O control

Number/type.................................

1 digital input/output (configurable), 1 digital input

Connector........................................

1 rear panel 9-pin female D connector (shared with the serial host port)

(1) 3.5 mm direct insertion captive screw connector (shared with power

sense port)

Pin configuration...........................

9-pin female D connector: 1 = digital input, 5 = GND;

power sense = digital in, GND = GND

Digital inputs

Input voltage range...........

0-12 VDC

Input impedance................

28k ohms

Programmable pullup.......

2k ohms to +5 VDC

Threshold low to high.......

>2.8 VDC

Threshold high to low.......

<2.0VDC

Digital output.................................

250 mA sink from 24 VDC, maximum

General

External power supply..................

100 VAC to 240 VAC, 50/60 Hz, external; to 12 VDC, 1 A, regulated

Power input requirements

MLC 226 IP DV+................

12 VDC, 0.515 A (includes MLC 226 IP and IRCM-DV+)

All other models................

12 VDC, 0.495 A (0.515 A with 1 IRCM-DV+ connected)

NAn MLC 226 Series controller must be powered by its own power supply. It cannot be powered by an MLS switcher.

Temperature/humidity.................

Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing

Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing

Cooling............................................

Convection, unvented

Rack mount

MLC 226 IP DV+................

No, but walland furniture-mountable

All other models................

Yes, with optional rack mounting kits, and also walland furniture-

mountable with optional mounting kits

Enclosure type

MLC 226 IP controller only. No faceplate, metal rear enclosure

MLC 226 IP, MLC 226 IP DV+

High-impact plastic faceplate, metal rear enclosure

MLC 226 IP with RAL9010 white faceplate, MLC 226 IP AAP, MLC 226 IP L

Metal faceplate, metal rear enclosure

Mlc 226 Ip

2 Extron MLC 226 Series MediaLink® Controllers • Specifications

Enclosure dimensions

MLC 226 faceplate.............

4.5' H x 6.4' W x 0.1' D (11.4 cm H x 16.3 cm W x 0.3 cm D) (3 gang)

MLC 226 AAP, MLC 226 IP DV+ faceplates

4.5' H x 10.0' W x 0.1' D (11.4 cm H x 25.4 cm W x 0.3 cm D) (5 gang)

MLC 226 L faceplate..........

3.15' H x 6.5' W x 0.1' D (8.0 cm H x 16.5 cm W x 0.3 cm D)

Device

MLC 226 IP DV+........

2.75' H x 5.3' W x 2.0' D (7.0 cm H x 13.5 cm W x 5.9 cm D) and

2.7' H x 2.6' W x 0.9' D (6.9 cm H x 6.6 cm W x 2.3 cm D)

(Depth excludes knob and buttons. Fits some 5 gang boxes. Allow at least

2.1' (5.3 cm) depth in the wall or furniture.)

2.1”

5.25'

2.7'

A

A

Extron MLC 226 Series MediaLink® Controllers • Specifications

3

Specifications — MLC 226 Series, cont’d

All other models........

2.75' H x 5.3' W x 2.0' D (7.0 cm H x 13.5 cm W x 5.9 cm D)

(Depth excludes knob and buttons. Fits some 3 gang boxes)

2.1”

5.25'

2.7'

6.4”

2.1”

5.25'

3.15”

2.7'

MLC 226 IP L Rear

4.5”

MLC 226 IP Rear

2.1”

5.25'

2.7'

4.5”

4 Extron MLC 226 Series MediaLink® Controllers • Specifications

Product weight

MLC 226 IP DV+................

2.1 lbs (1.0 kg)

All other models................

1.9 lbs (0.9 kg)

Shipping weight.............................

6 lbs (3 kg)

Vibration..........................................

ISTA 1A in carton (International Safe Transit Association)

Regulatory compliance

Safety...................................

CE, C-tick, CUL, UL

EMI/EMC...........................

CE, C-tick, FCC Class A, VCCI, ICES

Accessibility........................

Complies with the appropriate requirements of Section 508 of the

Rehabilitation Act (29U.S.C.794d).

MTBF...............................................

30,000 hours

Warranty..........................................

3 years parts and labor

N All nominal levels are at ±10%.

N Specifications are subject to change without notice.

7.6-070808-D12

Extron MLC 226 Series MediaLink® Controllers • Specifications

5

To continue the download you need to go through the captcha:

Mlc 104 ip plus series • setup guide, Contents mlc 104 ip plus series • setup guide 1, Panels and features

Advertising

1

MLC 104 IP Plus Series • Setup Guide

The Extron MLC 104 IP Plus Series MediaLink

®

Controller integrates Ethernet connection into AV systems to allow users

to remotely control, monitor, and troubleshoot AV equipment, including display devices and switchers. It includes an
embedded web server, serial ports, and configurable digital I/O ports for use in applications that require control and
monitoring of multiple devices within an AV system.
The MLC 104 IP Plus series of controllers are configured using the free Extron Global Configurator (GC) software. The
MLCs integrate seamlessly with Extron GlobalViewer

®

Enterprise (GVE) software and the free GlobalViewer web-based AV

resource management softwarefor remote control applications. Global Configurator and other useful software applications
are available at

A checklist of basic setup steps is provided at the end of this guide. For additional information see the help files and the
MLC 104 IP Plus Series User Guide, available at

Panels and Features

12

3

GROUND

+V OUT

Extron Mlc 226

CM

GROUND

IR OUT

GROUND

SCP

GROUND

Tx
Rx

DISPL

AY

RS-232/IR

A B C D

E

COMM LIN

K

AB

ML
S

RS-232

POWE

R

12V

DIGI

Extron Mlc 226 Ip User Manual

TA

L

I/O

IR IN

Tx

GROUND

Rx

+12V IN

PRESS

TAB
WITH

TWEEKER

TO

REMO

VE

LAN

PRE

SS

T

AB
WI

TH

TWEEKER

TO

RE
M

O

VE

LAN

CONFIG

DISPLAY

VOLUME

MLC 104 IP PLUS

Extron Mlc 104 Ip Plus

ON

VCR

DVD

PC

OFF

1

2

3

4

RESET

RUN

100

IR

Right Side

Rear Panel

Left Side

Top Panel

Front
Panel

Display On and

Off Buttons

Volume Knob

and LEDs

IR Learning

Receiver

Config (RS-232

host control) Port

Input Selection

Buttons

LAN (IP) Port

Reset Button

(recessed)

Reset LED

Digital I/O Ports (3)

Power Input (12 VDC)

Extron Mlc 226 Ip Aap

Control Module/IR/SCP

Port (COMM LINK)

Display or

Projector Control Port

MLS Switcher Port

Extron Mlc 226 Ip

Top Panel

Contents

Advertising
Table of contents
  • MLC 104 IP Plus Series • Setup Guide
    • Cabling and Features
    • About Global Configurator (GC)
    • Resources
    • Configuring for Network Communication
Popular Brands
Popular manuals