Specifications — MLC 226 Series
View and Download Extron electronics MLC 226 Series user manual online. MLC 226 Series Controller pdf manual download. Also for: Medialink mlc 226 series. Extron Electronics MLC 104 IP Plus Series Setup Guide User Manual. What to set up in gc, Control — serial (config) 4, Mlc 104 ip plus series. setup guide (continued), Players, and dvd players. Extron Electronics Hardware.
IP Intercom
Connection type (IPI–MLC)......... | RJ-45 jack for CAT 5, CAT 5e, or CAT 6 cable |
Audio | |
Frequency response........... | 20 Hz to 3.3 kHz, ±1 dB |
Audio processing | |
Audio format.............. | PCM, µ-law companded |
Sampling rate............. | 8 kHz |
Sample size................. | 16 bit, µ-law companded to 8 bit |
Audio latency............. | Software: 30 ms through 160 ms |
Network: <150 ms, typical | |
Audio output | |
Number/signal type......... | 1 mono (for use with an optional IP Intercom) |
Line level output................ | -10 dBV (316 mVrms), unbalanced (via 3.5 mm captive screw connector, |
2 pole) | |
Communication | |
Transport bandwidth for IPI control and audio, half duplex | |
80 kbps (0.08% of 100Base-T | |
Ethernet protocol............... | TCP/IP (control), UDP (audio) |
Control — host ports
Serial host port............................... | 2 bidirectional RS-232: 1 rear panel 9-pin female D connector (shared with |
digital input), 1 front panel 2.5 mm mini stereo jack | |
Baud rate and protocol.................. | 38400, 8 data bits, 1 stop bit, no parity |
Serial control pin configurations. | 9-pin female D connector: 2 = TX, 3 = RX, 5 = GND |
Mini stereo jack: tip = TX, ring = RX, sleeve = GND | |
Ethernet host port.......................... | 1 RJ-45 female |
Ethernet data rate (for network communication) | |
10/100Base-T, half/full duplex with autodetect | |
Ethernet protocol........................... | ARP, DHCP, ICMP (ping), TCP/IP, Telnet, HTTP, SMTP |
Ethernet default settings............... | Link speed and duplex level = autodetected |
IP address = 192.168.254.254 | |
Subnet mask = 255.255.0.0 | |
Default gateway = 0.0.0.0 | |
DHCP = off | |
Web server...................................... | Up to 200 simultaneous sessions |
7.25 MB nonvolatile user memory | |
Secondary control panel (SCP).... | (1) 3.5 mm 5-pole direct insertion captive screw connector (shared with |
control module and IR Link port) | |
IR remote control........................... | IR 402 (optional) |
Front panel: 30' maximum, 40 degrees off axis | |
Rear panel: 38 kHz, hardwired, modulated | |
Program control............................. | Extron's configuration program for Windows® |
Extron's Simple Instruction Set (SIS™) | |
Microsoft® Internet Explorer, Telnet | |
IR learning frequencies................. | 30 kHz to 62 kHz |
IR learning distance....................... | 2' (5.1 cm) to 12' (30.5 cm) from the front panel |
Control — relay
Number/type................................. | 6 momentary or latching (configurable via software) |
Connectors...................................... | (3) 3.5 mm captive screw connectors, 3 pole |
Connector configuration............... | Groups A, B, C; each with 1 common and 2 normally open relays (default) |
Contact rating................................. | 24 V, 1 A |
Extron MLC 226 Series MediaLink® Controllers • Specifications | 1 |
Specifications — MLC 226 Series, cont’d
Control — serial ports
Display control port...................... | (1) | 3.5 mm direct insertion captive screw connector, 3 pole, programmable |
for bidirectional RS-232 control (±5 V) or TTL level (0 to 5 V) infrared control | ||
up to 1 MHz | ||
Switcher control port..................... | (1) | 3.5 mm direct insertion captive screw connector, 3 pole, for bidirectional |
RS-232 control (±5 V)
Baud rate and protocol (RS-232).. 115200 to 300 baud (9600 baud = default); 8 (default) or 7 data bits; 1(default) or 2 stop bits; no parity (default), or even or odd parity
Control— IR/serial ports
IR/serial control ports................... | (3) 3.5 mm direct insertion captive screw connectors, 2 pole |
Programmable: unidirectional RS-232 (±5 V) control, or TTL level (0 to 5 V) | |
infrared control up to 1 MHz | |
Baud rate and protocol.................. | 115200 to 300 baud (9600 baud = default) ; 8 (default) or 7 data bits; |
1(default) or 2 stop bits; no parity (default), or even or odd parity |
Digital I/O control
Number/type................................. | 1 digital input/output (configurable), 1 digital input |
Connector........................................ | 1 rear panel 9-pin female D connector (shared with the serial host port) |
(1) 3.5 mm direct insertion captive screw connector (shared with power | |
sense port) | |
Pin configuration........................... | 9-pin female D connector: 1 = digital input, 5 = GND; |
power sense = digital in, GND = GND | |
Digital inputs | |
Input voltage range........... | 0-12 VDC |
Input impedance................ | 28k ohms |
Programmable pullup....... | 2k ohms to +5 VDC |
Threshold low to high....... | >2.8 VDC |
Threshold high to low....... | <2.0VDC |
Digital output................................. | 250 mA sink from 24 VDC, maximum |
General
External power supply.................. | 100 VAC to 240 VAC, 50/60 Hz, external; to 12 VDC, 1 A, regulated |
Power input requirements | |
MLC 226 IP DV+................ | 12 VDC, 0.515 A (includes MLC 226 IP and IRCM-DV+) |
All other models................ | 12 VDC, 0.495 A (0.515 A with 1 IRCM-DV+ connected) |
NAn MLC 226 Series controller must be powered by its own power supply. It cannot be powered by an MLS switcher.
Temperature/humidity................. | Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing |
Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing | |
Cooling............................................ | Convection, unvented |
Rack mount | |
MLC 226 IP DV+................ | No, but walland furniture-mountable |
All other models................ | Yes, with optional rack mounting kits, and also walland furniture- |
mountable with optional mounting kits | |
Enclosure type |
MLC 226 IP controller only. No faceplate, metal rear enclosure
MLC 226 IP, MLC 226 IP DV+
High-impact plastic faceplate, metal rear enclosure
MLC 226 IP with RAL9010 white faceplate, MLC 226 IP AAP, MLC 226 IP L
Metal faceplate, metal rear enclosure
Mlc 226 Ip
2 Extron MLC 226 Series MediaLink® Controllers • Specifications
Enclosure dimensions | |
MLC 226 faceplate............. | 4.5' H x 6.4' W x 0.1' D (11.4 cm H x 16.3 cm W x 0.3 cm D) (3 gang) |
MLC 226 AAP, MLC 226 IP DV+ faceplates
4.5' H x 10.0' W x 0.1' D (11.4 cm H x 25.4 cm W x 0.3 cm D) (5 gang)
MLC 226 L faceplate.......... | 3.15' H x 6.5' W x 0.1' D (8.0 cm H x 16.5 cm W x 0.3 cm D) |
Device | |
MLC 226 IP DV+........ | 2.75' H x 5.3' W x 2.0' D (7.0 cm H x 13.5 cm W x 5.9 cm D) and |
2.7' H x 2.6' W x 0.9' D (6.9 cm H x 6.6 cm W x 2.3 cm D) | |
(Depth excludes knob and buttons. Fits some 5 gang boxes. Allow at least | |
2.1' (5.3 cm) depth in the wall or furniture.) |
2.1”
5.25'
2.7'
A
A
Extron MLC 226 Series MediaLink® Controllers • Specifications | 3 |
Specifications — MLC 226 Series, cont’d
All other models........ | 2.75' H x 5.3' W x 2.0' D (7.0 cm H x 13.5 cm W x 5.9 cm D) |
(Depth excludes knob and buttons. Fits some 3 gang boxes) |
2.1”
5.25'
2.7'
6.4”
2.1”
5.25'
3.15”
2.7'
MLC 226 IP L Rear
4.5”
MLC 226 IP Rear
2.1”
5.25'
2.7'
4.5”
4 Extron MLC 226 Series MediaLink® Controllers • Specifications
Product weight | |
MLC 226 IP DV+................ | 2.1 lbs (1.0 kg) |
All other models................ | 1.9 lbs (0.9 kg) |
Shipping weight............................. | 6 lbs (3 kg) |
Vibration.......................................... | ISTA 1A in carton (International Safe Transit Association) |
Regulatory compliance | |
Safety................................... | CE, C-tick, CUL, UL |
EMI/EMC........................... | CE, C-tick, FCC Class A, VCCI, ICES |
Accessibility........................ | Complies with the appropriate requirements of Section 508 of the |
Rehabilitation Act (29U.S.C.794d). | |
MTBF............................................... | 30,000 hours |
Warranty.......................................... | 3 years parts and labor |
N All nominal levels are at ±10%.
N Specifications are subject to change without notice.
7.6-070808-D12
Extron MLC 226 Series MediaLink® Controllers • Specifications | 5 |
Mlc 104 ip plus series • setup guide, Contents mlc 104 ip plus series • setup guide 1, Panels and features
1
MLC 104 IP Plus Series • Setup Guide
The Extron MLC 104 IP Plus Series MediaLink
®
Controller integrates Ethernet connection into AV systems to allow users
to remotely control, monitor, and troubleshoot AV equipment, including display devices and switchers. It includes an
embedded web server, serial ports, and configurable digital I/O ports for use in applications that require control and
monitoring of multiple devices within an AV system.
The MLC 104 IP Plus series of controllers are configured using the free Extron Global Configurator (GC) software. The
MLCs integrate seamlessly with Extron GlobalViewer
®
Enterprise (GVE) software and the free GlobalViewer web-based AV
resource management softwarefor remote control applications. Global Configurator and other useful software applications
are available at
A checklist of basic setup steps is provided at the end of this guide. For additional information see the help files and the
MLC 104 IP Plus Series User Guide, available at
Panels and Features
12
3
GROUND
+V OUT
Extron Mlc 226
CM
GROUND
IR OUT
GROUND
SCP
GROUND
Tx
Rx
DISPL
AY
RS-232/IR
A B C D
E
COMM LIN
K
AB
ML
S
RS-232
POWE
R
12V
DIGI
TA
L
I/O
IR IN
Tx
GROUND
Rx
+12V IN
PRESS
TAB
WITH
TWEEKER
TO
REMO
VE
LAN
PRE
SS
T
AB
WI
TH
TWEEKER
TO
RE
M
O
VE
LAN
CONFIG
DISPLAY
VOLUME
MLC 104 IP PLUS
Extron Mlc 104 Ip Plus
ON
VCR
DVD
PC
OFF
1
2
3
4
RESET
RUN
100
IR
Right Side
Rear Panel
Left Side
Top Panel
Front
Panel
Display On and
Off Buttons
Volume Knob
and LEDs
IR Learning
Receiver
Config (RS-232
host control) Port
Input Selection
Buttons
LAN (IP) Port
Reset Button
(recessed)
Reset LED
Digital I/O Ports (3)
Power Input (12 VDC)
Extron Mlc 226 Ip Aap
Control Module/IR/SCP
Port (COMM LINK)
Display or
Projector Control Port
MLS Switcher Port
Extron Mlc 226 Ip
Top Panel
Contents
- MLC 104 IP Plus Series • Setup Guide
- Cabling and Features
- About Global Configurator (GC)
- Resources
- Configuring for Network Communication