Gb Instruments Gdt 292a User Manual

Unit powers on and displays various numbers and symbols on the screen. Gb Instruments Multimeter Gdt 200a Manual GB Instruments GMT-12A GMT-12 A manual, instructions gdt-11 multimeter manual gb instruments gdt-11 user manual' none. Gb gdt 200a manual documents platformusers.net gb gdt 200a multimeter Free tech support for Gardner Bender #GDT-200A 7 Func Digital Multitester and help with user manual. Gdt 295a Manual - www.transactionbooks.com. Operators instruction manuals gardner bender cj5 manual gdt-292a user manual 500 manual gdt 294a manual indiana chauffeur license guide gb instruments gdt-292a instruction manual tomos outboard manual gx25 honda 4 stroke owners manual 8 hp service manual vitamix 5200 manual. GB Instruments digital multimeter is model GDT-292A.  The mulitmeter features a 10Amp max input, rubber exterior housing, DC volt 0-7,000, AC volt 0-700, and a power on/off button.  Condition: Untested - Sold as-is This item is untested due to lack of proper equipment. Test Instruments. Testing equipment can be put to good use ensuring that electrical equipment is properly installed and safe to operate. Faulty installations can be lethal; the condition of electrical installations can be established when contractors use test equipment.

Gb instruments gdt 292a manual Gb Instruments Gdt 292a Manual GB INSTRUMENTS GDT 11 USER MANUAL - To download just click GDT-294A lost owners manual, want to know which selector to use to check Gb instruments gdt- 294a digital multimeter exc - gb instruments gdt-294a digital multimeter exc added to cart. Instruction manual, bench stand approval.

Digital Multimeter image by TekinT from Fotolia.com

Gardner Bender’s GDT-11 is a handheld digital multimeter with a 3 1/2-digit liquid crystal numeric display. The meter measures volts for direct and alternating currents, resistance and DC current. In addition, the unit has a diode check feature.

Preparing Meter and Battery

Snap the battery clip onto one of the batteries; set the battery aside for measuring voltage and current.

Plug the red test probe into the meter socket marked VΩmA.

Plug the black test probe into the meter socket marked COM.

Rotate the function selector knob to any setting other than OFF. If the display does not turn on, or if you see the BAT indicator on the display, replace the meter’s internal 9-volt battery with a fresh one.

Tip

Measurements of a 9-volt battery are safe as the voltage is too low to pose a shock hazard.

DC Voltage

Rotate the function selector knob until it points to the 20 range in the DC voltage scale, indicating a maximum of 20 volts. The DC voltage scale is indicated by the V-- symbol on the meter.

Touch the metal tip of the red meter probe to the positive wire of the battery clip; usually this is the red wire. Touch the tip of the black probe to the negative wire, which is black.

Read the voltage indicated on the meter’s LCD display. The meter should measure roughly 9 volts.

Tip

You can measure voltage or current with the probe polarity reversed; however, the meter will display a negative number. This does not adversely affect the meter or the components you’re testing.

Warning

Avoid touching the metal probe tips when measuring voltages greater that 50V; high voltages pose a shock hazard.

Resistance

Rotate the function selector knob until it points to the 200 range on the meter’s resistance scale, indicated by the symbol.

Touch the red meter probe tip to one of the resistor’s leads. Touch the black probe to the remaining resistor lead.

Instruments

Read the resistance on the meter’s display. You should see a reading of about 100 ohms; a few percent higher or lower is normal.

Warning

Gb Instruments Gdt-292a User Manual

  • Do not touch the metal probe tips when measuring resistance; the resistance of your skin will affect the meter’s accuracy.
  • Do not attempt to measure resistance for circuits or components that are powered on or have currents running through them; you might blow the meter’s fuse or damage the unit.

DC Current

Gb Instruments Gdt-292a Manual

Wrap the positive battery clip wire around one of the leads of the resistor.

Rotate the function selector knob until it points to the 200 range in the meter’s DC current scale, indicated by the A-- symbol.

Touch the tip of the red meter probe to the free lead of the resistor. Touch the tip of the black meter probe to the negative battery clip wire.

Read the current value on the meter’s display. You should see a reading of about 90 milliamps or .09 amps.

Warning

Do not attempt to measure currents in excess of 200 milliamps unless the red meter probe is plugged into the 10A DC socket and the selector knob points to the 10A-- range.

Always measure current with a resistance connected in series with a battery or other power source; the resistance limits the current and avoids a potentially damaging short circuit.