Glow Worm Ultracom 12hxi User Manual

Advertising

SERVICE INTERVAL RECORD

  1. View online User manual manual for Glow-worm 38cxi Boiler or simply click Download button to examine the Glow-worm 38cxi guidelines offline on your desktop or laptop computer. Glow-worm Ultracom 12hxi Installation And Servicing Installation and servicing (60 pages) Glow-worm.
  2. Boiler Manuals and Literature Downloads. All of Glow-worm's boiler and control product literature, collected together in one place. Search for, view and download installation and service manuals for any one of our award-winning domestic boiler and heating control products.

It is recommended that your heating system is serviced regularly

and that you complete the appropriate Service Interval Record Below .

Nov 24, 2018  Glow Worm Ultracom Hxi 12 15 18 24 30 38 User Manual → Disclaimer: Information on this website is provided for informational purpose therefore we cannot accept liability for subsequent problems. All repair tasks should be carried out by qualified trades people. View and Download Glow-worm Ultracom hxi instructions for use manual online. High efficiency condensing system boilers. Ultracom hxi Boiler pdf manual download. Glow-worm ultracom hxi Instructions For Use Manual. Boiler Glow-worm Ultracom 12hxi Installation And Servicing Manual. Listed below are all the Glowworm USER manuals. Just click on the model or the Gas council number and the manual will download at the bottom of the page, when the download has finished double click the download and the manual will open right click to save.

Service Provider. Before completing the appropriate Service Interval Record below, please ensure you have carried out the service

as described in the boiler manufacturer’s instructions. Always use the manufacturer ‘s specified spare part when replacing all controls.

SERVICE 1

Date

Energy Effi ciency Checklist completed?

Yes

No

Engineer Name
Company Name
Telephone Number
Engineer ID Number
Comments

Signature

SERVICE 3

Date

Energy Effi ciency Checklist completed?

Yes

No

Engineer Name
Company Name
Telephone Number
Engineer ID Number
Comments

Signature

SERVICE 5

Date

Energy Effi ciency Checklist completed?

Yes

No

Engineer Name
Company Name
Telephone Number
Engineer ID Number
Comments

Signature

SERVICE 7

Date

Energy Effi ciency Checklist completed?

Yes

No

Engineer Name
Company Name
Telephone Number
Engineer ID Number
Comments

Signature

SERVICE 9

Date

Energy Effi ciency Checklist completed?

Yes

No

Engineer Name
Company Name
Telephone Number
Engineer ID Number
Comments

Signature

SERVICE 2

Date

Energy Effi ciency Checklist completed?

Yes

No

Engineer Name
Company Name
Telephone Number
Engineer ID Number
Comments

Signature

SERVICE 4

Date

Energy Effi ciency Checklist completed?

Yes

No

Engineer Name
Company Name
Telephone Number
Engineer ID Number
Comments

Signature

SERVICE 6

Date

Energy Effi ciency Checklist completed?

Yes

No

Engineer Name
Company Name
Telephone Number
Engineer ID Number
Comments

Signature

SERVICE 8

Date

Energy Effi ciency Checklist completed?

Yes

No

Engineer Name
Company Name
Telephone Number
Engineer ID Number
Comments

Signature

SERVICE 10

Date

Energy Effi ciency Checklist completed?

Yes

No

Engineer Name
Company Name
Telephone Number
Engineer ID Number
Comments

Signature

Advertising
Popular Brands
Popular manuals
Advertising

0020107233_00 - 06/11 - Glow-worm

INSTALLATION

- 13 -

4.2.3

Multiple boiler chimney flue

Ø 60/100 mm (C43 type installation)

The flue connecting from the appliance to

the flue system must be supplied from the

Glow worm ultracom 12hxi installation manual

manufacturer of the boiler.

C43 flue systems must not be a 'pressurised

system' but act under natural draught

principles

C43 type flue systems must have their

own condensate drain fitted and not allow

condensate to mix into other appliances

Multiple boiler Chimney flue length

The flue length must be calculated and installed according to

the relevant standards EN 13384-1 and 2 (C43 flue systems

only) with reference to the table below and the manufacturers

instructions supplied.

The appliance maximum flue length must be included when

calculating the overall design of the flue system.

noTe: The horizontal flue terminal must be removed.

MoDel

Ultracom

12hxi

Ultracom

15hxi

Ultracom

18hxi

Ultracom

24hxi

Ultracom

30hxi

Ultracom

38hxi

exhaust mass rate (g/s)
At Min Thermal
Load (40C°/30°C)

2.30

2.30

2.30

2.45

2.45

3.10

At Max Thermal
Load (80C°/60°C)

5.65

7.10

8.75

11.30

13.25

18.30

exhaust temperature (ºC)
At Min Thermal
Load (40C°/30°C)

56.0

56.0

56.0

44.0

44.0

46.0

At Max Thermal
Load (80C°/60°C)

69.0

70.0

69.0

66.0

57.0

73.0

L

B

A

1

2

3

4

5

Key

1 Pressure balancing system

2 air-inlet pipe

3 Collector pipe

4 boiler

5 Inspection hatch

a final storey

b Ground floor

Type

Max length (l)

Ø 60/100

10 m

Glow Worm Ultracom 12hxi Boiler Manual

Each time an additional 90° bend is necessary (or 2 at 45°),

the length (L) must be reduced by 1 m.

Glow Worm Ultracom 12hxi Manual